更新时间:2017-08-17 11:26:52
A customer is claiming that his tool doesn’t bring the performance shown in the specs: UNIMAT doesn’t reach the maximum set temperature / UNIPLAN doesn’t weld with full speed / TRIAC doesn’t reach temperature / and so on
有很多客户抱怨机器走的慢,温度达不到期望值!
In most of these cases “low voltage” is the reason. It can be caused by:
多数情况是由于供电压太低导致:
Bad power supply (weak generator, low voltage supply) 发电机电压低
Bad extension cable (too thin, too long, half broken cables) 电源延长线不合适
Bad junctions (old sockets, old plugs, bad fixation of cable to plug, wrong plugs, no plugs, …) 劣质的插头
Too many power tools on one power source 多台设备在一个电源下同时使用
怎样测量?
1.正确的方式
Always measure as close as possible to the tool with a two way adaptor while the machine is heating!
在设备正常加热的情况下测量电压!靠近设备的地方测量!
Double plug right before the tool, while it is heating up.
If you measure the voltage just before the tool on load, you can see what voltage the tool gets while working.
2.不正确的方式
Don’t measure directly at the power supply! 不要测量电源插头处
If low voltage is displayed, you know there is a problem
If the right voltage is displayed, you don’t know whether the power supply at the machine is okay or not.
Don’t measure directly after at the end of the extension cord!
不要直接测量连接线的尾端!
If low voltage is displayed, you know there is a problem.
If the right voltage is displayed, you don’t know whether the power supply is OK. This can only be tested when the power is under load.
Don’t measure with double plug just before the tool without switching it on! 不要在机器不工作的情况下测量!
If low voltage is displayed, you know there is a problem.
If the right voltage is displayed, you don’t know whether the power supply it is OK. Only measure while machine is heating.